# Variable Speed Drive, Altivar Process ATV900, ATV930, 4kW, 400 to 480V, with braking unit, IP21 [TAA, BAA, BABA]

- Link: https://danfossexpress.com/product/variable-speed-drive-altivar-process-atv900-atv930-4kw-400-to-480v-with-braking-unit-ip21-taa-baa-baba/
- Published: 2026-02-16T15:47:01+00:00
- Author: drivesexperts

## Variable Speed Drive, Altivar Process ATV900, ATV930, 4kW, 400 to 480V, with braking unit, IP21 [TAA, BAA, BABA]

**Manufacturer:** Schneider Electric

**Part Number:** ATV930U40N4US

### Key Specifications

 |  **Range of Product** |  Altivar Process ATV900 |  
 |  **Phase** |  3 phase |  
 |  **Mounting Mode** |  Wall mount |  
 |  **Continuous output current** |  9.3 A 4 kHz normal duty | 7.2 A 4 kHz heavy duty |  
 |  **[Us] rated supply voltage** |  380…480 V |  
 |  **Relative symmetric mains voltage tolerance** |  10 % |  
 |  **Relative symmetric network frequency tolerance** |  5 % |  
 |  **nominal output current** |  9.3 A |  
 |  **Motor power kW** |  4.0 kW normal duty | 3.0 kW heavy duty |  
 |  **IP degree of protection** |  IP21 |  
 |  **Maximum switching current** |  Relay output R1 resistive, cos phi = 1 3 A 250 V AC | Relay output R1 resistive, cos phi = 1 3 A 30 V DC | Relay output R1 inductive, cos phi = 0.4 7 ms 2 A 250 V AC | Relay output R1 inductive, cos phi = 0.4 7 ms 2 A 30 V DC | Relay output R2, R3 resistive, cos phi = 1 5 A 250 V AC | Relay output R2, R3 resistive, cos phi = 1 5 A 30 V DC | Relay output R2, R3 inductive, cos phi = 0.4 7 ms 2 A 250 V AC | Relay output R2, R3 inductive, cos phi = 0.4 7 ms 2 A 30 V DC |  
 |  **Minimum switching current** |  Relay output R1, R2, R3 5 mA 24 V DC |  
 |  **Maximum output frequency** |  599 Hz |  
 |  **Switching frequency** |  2…16 kHz adjustable | 4…16 kHz with derating factor |  
 |  **Nominal switching frequency** |  4 kHz |  
 |  **Line current** |  7.6 A 380 V normal duty) | 6.0 A 380 V heavy duty) | 6.7 A 480 V normal duty) | 5.4 A 480 V heavy duty) |  
 |  **Maximum Input Current per Phase** |  7.6 A |  
 |  **Maximum output voltage** |  480.0 V |  
 |  **Apparent power** |  5.6 kVA 480 V normal duty) | 4.5 kVA 480 V heavy duty) |  
 |  **Maximum transient current** |  11.2 A 60 s normal duty) | 10.8 A 60 s heavy duty) |  
 |  **Network Frequency** |  50-60 Hz |  
 |  **Base load current at high overload** |  7.2 A |  
 |  **Base load current at low overload** |  9.3 A |  
 |  **Power dissipation in W** |  Natural convection 33 W 380 V 4 kHz | Forced convection 97 W 380 V 4 kHz |  
 |  **Net Weight** |  10.1 lb(US) (4.6 kg) |  
 |  **Overvoltage category** |  III |  
 |  **Package weight(Lbs)** |  13.735 lb(US) (6.230 kg) |

### Downloads

 * [📥 User guide](https://download.schneider-electric.com/files?p_enDocType=User+guide&p_File_Name=ATV900_Programming_Manual_EN_NHA80757_13.pdf&p_Doc_Ref=NHA80757)