Variable Speed Drive, Altivar Process ATV600, ATV630, 30kW, 40hp, 200 to 240V, IP21, UL type 1 [TAA, BABA]
Manufacturer: Schneider Electric
Part Number: ATV630D30M3US
Key Specifications
| Range of Product | Altivar Process ATV600 |
| Mounting Mode | Wall mount |
| [Us] rated supply voltage | 200…240 V |
| Relative symmetric mains voltage tolerance | 10 % |
| Relative symmetric network frequency tolerance | 5 % |
| nominal output current | 123.0 A |
| IP degree of protection | IP21IEC 61800-5-1 | IP21IEC 60529 |
| Supply frequency | 50…60 Hz – 5…5 % |
| Motor power kW | 30 kW normal duty) | 22 kW heavy duty) |
| Maximum Horse Power Rating | 40 hp normal duty | 30 hp heavy duty |
| Line current | 104.7 A 200 V normal duty) | 88.6 A 240 V normal duty) | 78.3 A 200 V heavy duty) | 67.1 A 240 V heavy duty) |
| Continuous output current | 123 A 2.5 kHz normal duty | 92.6 A 2.5 kHz heavy duty |
| Speed drive output frequency | 0.1…500 Hz |
| Maximum switching current | Relay output R1, R2, R3 resistive, cos phi = 1 3 A 250 V AC | Relay output R1, R2, R3 resistive, cos phi = 1 3 A 30 V DC | Relay output R1, R2, R3 inductive, cos phi = 0.4 7 ms 2 A 250 V AC | Relay output R1, R2, R3 inductive, cos phi = 0.4 7 ms 2 A 30 V DC |
| Minimum switching current | Relay output R1, R2, R3 5 mA 24 V DC |
| Phase | 3 phase |
| Output voltage | <= power supply voltage |
| Permissible temporary current boost | 1.1 x In 60 s normal duty) | 1.5 x In 60 s heavy duty) |
| Frequency resolution | Display unit 0.1 Hz | Analog input 0.012/50 Hz |
| Power range | 30…50 kW 200…240 V 3 phase |
| Enclosure mounting | Wall mounted |
| Maximum output frequency | 500 kHz |
| Switching frequency | 2.5…8 kHz with derating factor | 2…8 kHz adjustable |
| Nominal switching frequency | 2.5 kHz |
| Maximum Input Current per Phase | 104.7 A |
| Maximum output voltage | 240.0 V |
| Apparent power | 36.8 kVA 240 V normal duty) | 27.9 kVA 240 V heavy duty) |
| Maximum transient current | 135.3 A 60 s normal duty) | 138.9 A 60 s heavy duty) |
| Network Frequency | 50-60 Hz |
| Base load current at high overload | 92.6 A |
| Base load current at low overload | 123.0 A |
| Power dissipation in W | Natural convection 129 W 200 V 2.5 kHz | Forced convection 862 W 200 V 2.5 kHz |
| Net Weight | 124.8 lb(US) (56.6 kg) |
| Overvoltage category | III |
| Package weight(Lbs) | 121.3 lb(US) (55.0 kg) |

![Variable Speed Drive, Altivar Process ATV600, ATV630, 30kW, 40hp, 200 to 240V, IP21, UL type 1 [TAA, BABA]](https://danfossexpress.com/wp-content/uploads/2026/02/ATV630D30M3US.jpg)