# NXA03855-A0T02SG-A1A2B50000+ARFIFF05+GSNT+EMAR+LPC2+SPXE – VACON® NXP Common DC Bus 259 kW, IP00, 380–500 V

- Link: https://danfossexpress.com/product/nxa03855-a0t02sg-a1a2b50000arfiff05gsntemarlpc2spxe/
- Published: 2025-05-06T11:00:38+00:00
- Author: drivesexperts

## NXA03855-A0T02SG-A1A2B50000+ARFIFF05+GSNT+EMAR+LPC2+SPXE overview

**NXA03855-A0T02SG-A1A2B50000+ARFIFF05+GSNT+EMAR+LPC2+SPXE** is a VACON® NXP Common
DC Bus active front-end unit rated 259 kW (385 A continuous output current) for 
three-phase 380–500 V mains supply. It is built in an IP00 enclosure, frame size
FI10, measures 1030 × 239 × 552 mm (H × W × D) and weighs 97 kg net (98 kg packed).

Danfoss ordering number: 137X1568, EAN 5715253802022.

## Configuration

 * EMC category C4
 * Alphanumeric Keypad control panel
 * I/O: 6DI,DO,2AI,1AO,+10Vr,+24V

## Model code breakdown

What each part of NXA03855-A0T02SG-A1A2B50000+ARFIFF05+GSNT+EMAR+LPC2+SPXE means:

  |  Position |  Code |  Meaning |  
   |  Product Group |  NXA |  Active Front-End Unit |  
 |  Customized Drive |  +BM26 |  Vacon Dark Grey NXP |  
 |  Mechanical Modification |  S |  Standard air cooled drive |  
 |  Mains voltage |  5- |  380 – 500 Vac (465-800 Vdc) |  
 |  Current |  0385 |  385 Amp |  
 |  Control Keypad |  A |  Alpha-numeric display |  
 |  Enclosure |  0 |  IP00 |  
 |  EMC emission levels |  T |  IEC61800-3 for IT networks |  
 |  Brake Chopper |  0 |  No Brake |  
 |  Electrical Modification |  2 |  AFE module w/o LCL |  
 |  Card Modifications |  G- |  FiberConnection+Varnished PCB |  
 |  Shipping Package |  +GSNT |  Without packaging |  
 |  Warranty |  +WT01 |  Warranty 12/18 months |  
 |  Gland Plate Option |  +QGNO |  No conduit plate |  
 |  Option Slot A |  A1 |  6DI,DO,2AI,1AO,+10Vr,+24V |  
 |  Option Slot B |  A2 |  2RO(NO/NC) |  
 |  Option Slot C |  B5 |  3RO(NO) |  
 |  Option Slot D |  00 |  No board |  
 |  Option Slot E |  00 |  No board |  
 |  Firmware language package |  +FL22 |  UK,FR,IT,ES,PT;WestEur |  
 |  Documentation Level |  +DPAP |  Paper manuals |  
 |  Documentation Lang. Preference |  +DLUK |  English |  
 |  System Firmware |  +FNP02 |  System software NXP |  
 |  Software license |  NONE |  no software license |  
 |  Application |  +ARFIFF05 |  AFE II application NXA,NXI,NXP |  
 |  Parameter Set |  NONE |  none |  
 |  Motor Parameter Default |  +LS50 |  Default Motor frequency 50HZ |  
 |  Labeling options |  +LPC2 |  Two sets of product labels |  
 |  CE Approval |  +GACE |  CE Approval |  
 |  UL Approval |  +GAUL |  UL approval |  
 |  RCM Approval |  +GACT |  RCM Approval N16307 |  
 |  Marine approval |  +EMAR |  Marine Approval |  
 |  KC Approval |  +GAKC |  Korean Approval |  
 |  Ukrainian Approval |  +GAUA |  Ukrainian Approval |  
 |  EAC Approval |  +GAEA |  EAC Approval |

## Same configuration, other power sizes

 * [874 kW: NXA13005-A0T02SG-A1A2B50000+ARFIFF05+GSNT+EMAR+LPC2+SPXE](https://danfossexpress.com/product/nxa13005-a0t02sg-a1a2b50000arfiff05gsntemarlpc2spxe/)

Need a price or lead time for NXA03855-A0T02SG-A1A2B50000+ARFIFF05+GSNT+EMAR+LPC2
+SPXE? Send the model code or ordering number with your quantity and delivery country,
and we will reply with a quotation. See [how to request a quote](https://danfossexpress.com/how-to-request-a-quote/).