# NXA01708-A0T02WG-ANA200B5E9+MASG+ARFIFF03 – VACON® NXP Liquid Cooled Common DC Bus 180 kW, IP00, 525–690 V

- Link: https://danfossexpress.com/product/nxa01708-a0t02wg-ana200b5e9masgarfiff03/
- Published: 2025-05-06T11:09:38+00:00
- Author: drivesexperts

## NXA01708-A0T02WG-ANA200B5E9+MASG+ARFIFF03 overview

**NXA01708-A0T02WG-ANA200B5E9+MASG+ARFIFF03** is a VACON® NXP Liquid Cooled Common
DC Bus active front-end unit rated 180 kW (155 A continuous output current) for 
three-phase 525–690 V mains supply. It is built in an IP00 enclosure, frame size
CH61, measures 658 × 246 × 374 mm (H × W × D) and weighs 55 kg net (56 kg packed).

Danfoss ordering number: 137N8235, EAN 5715253663647.

## Configuration

 * EMC category C4
 * Alphanumeric Keypad control panel
 * I/O: 6DI,2AI,2AO,10/-10Vref,24V

## Model code breakdown

What each part of NXA01708-A0T02WG-ANA200B5E9+MASG+ARFIFF03 means:

  |  Position |  Code |  Meaning |  
   |  Product Group |  NXA |  Active Front-End Unit |  
 |  Customized Drive |  +BM26 |  Vacon Dark Grey NXP |  
 |  Mechanical Modification |  W |  Liquid cooling |  
 |  Mains voltage |  8- |  525 – 690 Vac (640-1200 Vdc) |  
 |  Current |  0170 |  170 Amp |  
 |  Control Keypad |  A |  Alpha-numeric display |  
 |  Enclosure |  0 |  IP00 |  
 |  EMC emission levels |  T |  IEC61800-3 for IT networks |  
 |  Brake Chopper |  0 |  No Brake |  
 |  Electrical Modification |  2 |  AFE module w/o LCL |  
 |  Card Modifications |  G- |  FiberConnection+Varnished PCB |  
 |  Shipping Package |  +GSCB |  Cardboard box as Shipping pack |  
 |  Warranty |  +WT01 |  Warranty 12/18 months |  
 |  Gland Plate Option |  +QGNO |  No conduit plate |  
 |  Option Slot A |  AN |  6DI,2AI,2AO,10/-10Vref,24V |  
 |  Option Slot B |  A2 |  2RO(NO/NC) |  
 |  Option Slot C |  00 |  No board |  
 |  Option Slot D |  B5 |  3RO(NO) |  
 |  Option Slot E |  E9 |  2-port ethernet |  
 |  Firmware language package |  +FL22 |  UK,FR,IT,ES,PT;WestEur |  
 |  Documentation Level |  +DPAP |  Paper manuals |  
 |  Documentation Lang. Preference |  +DLUK |  English |  
 |  System Firmware |  +FNP02 |  System software NXP |  
 |  Software license |  +MASG |  Grid Converter license |  
 |  Application |  +ARFIFF03 |  Grid Converter NXA,NXI,NXP |  
 |  Parameter Set |  NONE |  none |  
 |  Motor Parameter Default |  +LS50 |  Default Motor frequency 50HZ |  
 |  Labeling options |  +LPC1 |  no additional labels |  
 |  CE Approval |  +GACE |  CE Approval |  
 |  UL Approval |  +GAUL |  UL approval |  
 |  RCM Approval |  +GACT |  RCM Approval N16307 |  
 |  Marine approval |  NONE |  no marine approval |  
 |  KC Approval |  +GAKC |  Korean Approval |  
 |  Ukrainian Approval |  +GAUA |  Ukrainian Approval |  
 |  EAC Approval |  +GAEA |  EAC Approval |