FCD302PK75T4B66H1S1FMFCEXXXXAXBXXXXXXDX overview
FCD302PK75T4B66H1S1FMFCEXXXXAXBXXXXXXDX is a VLT® Decentral Drive FCD 302 rated 0.75 kW / 1 HP for three-phase 380–480 V mains supply. It is built in an Standard Black IP66/NEMA4X enclosure, frame size MF1 and weighs 9.8 kg net (10.1 kg packed).
Danfoss ordering number: 130B7941, EAN 5710107948710.
Configuration
- RFI filter Class A1 (EMC category C2)
- Built-in brake chopper
- Display connector control panel
Model code breakdown
What each part of FCD302PK75T4B66H1S1FMFCEXXXXAXBXXXXXXDX means:
| Position | Code | Meaning |
|---|---|---|
| Product Group | FCD | VLT® DecentralDrive FCD |
| VLT Series | 302 | 302 |
| Power Rating | PK75 | 0.75 kW / 1.0 HP |
| Mains Voltage | T4 | 380-480VAC (Three phased) |
| Enclosure | B66 | Standard Black IP66/NEMA4X |
| RFI Filter | H1 | RFI Class A1/C2 |
| Brake | S | Brake chop. + mech. brake |
| Hardware Configuration | 1 | Compl. small stand alone |
| Brackets | F | 40 mm brackets |
| Threads | M | Metric threads |
| Switch Option | F | Service switch motor side |
| Display | C | With display connector |
| Sensor Plugs | E | Direct mount 4xM12 |
| Motor Plug | X | No motor plug |
| Mains Plug | X | No mains plug |
| Fieldbus Plug | X | No fieldbus plug |
| Reserved | X | Reserved |
| A Option | AX | No fieldbus option |
| B Option | BX | No B option |
| Reserved for SW | XXXXX | Reserved for SW |
| D Option | DX | No option |
| FCD302 Frame Size | MF1 | (MF1) MF1 |
Same configuration, other power sizes