Frequency converter
FC-302N110T7E21H2BGCXXXSXXXXA0BRCXXXXD0
VLT® AutomationDrive FC-302
(N110) 110 KW / 150 HP, Specific Ratings: 90kW@525-550V, 125HP@575V, 110kW@690V
Three phase, 525 – 690 VAC *,IP21 / Type 1
RFI Filter
Brake chopper
Graphical Loc. Cont. Panel
Coated PCB, No Mains Option
Latest release std. SW.
Frame: D5H
PROFIBUS DP MCA 101, MCB-102 Encoder Option
No C1 option, MCB-107 24V DC backup
Other options according to Model code
Model code:
FC-302N110T7E21H2BGCXXXSXXXXA0BRCXXXXD0
The VLT® AutomationDrive represents a single drive concept that controlsthe entire range of operations from ordinary to servo like applicationson any machine or production line.
| Gross weight | 166.3 Kilogram | ||
| Net weight | 166 Kilogram | ||
| EAN | 5715253814018 |
| Product View (Switch) | GLBL | Global (Standard) | |
| Product Group | FC- | VLT® AutomationDrive FC- | |
| Series | 302 | 302 | |
| Power Rating | N110 | (N110) 110 KW / 150 HP | |
| Phase | T | Three phase | |
| Mains Voltage | 7 | 525 – 690 VAC * | |
| Possible rating issue | WARN01 | Possible Rating Issue: | |
| Enclosure | E21 | IP21 / Type 1 | |
| RFI Filter | H2 | RFI Filter | |
| Brake – Safe Stop | B | Brake chopper | |
| LCP | G | Graphical Loc. Cont. Panel | |
| Coating PCB | C | Coated PCB | |
| Mains Option | X | No Mains Option | |
| Adaptation A | X | Standard Cable Entries | |
| Adaptation B | X | No adaptation | |
| Software Release | SXXX | Latest release std. SW. | |
| Software Language Pack | X | Standard Language Pack | |
| A Option | A0 | PROFIBUS DP MCA 101 | |
| B Option | BR | MCB-102 Encoder Option | |
| C0 Option MCO | CX | No C0 option | |
| C1 Option | X | No C1 option | |
| C Option Software | XX | No software option | |
| D Option | D0 | MCB-107 24V DC backup | |
| Frame Size | D5H | D5H | |
| Typecode Part 1 | FC-302N110T7E21H2BGC | ||
| Typecode Part 2 | XXXSXXXXA0BRCXXXXD0 | ||
| Product Catalog | NO_VIEW | NO VIEW | |
| Power 150% (HO) [KW] | 110 | 110 | |
| Power 110% (NO) [KW] | 132 | 132 | |
| Height [mm] | 1324,0 | 1324,0 | |
| Width w/ no C options [mm] | 325,0 | 325,0 | |
| Depth [mm] | 381,0 | 381,0 | |
| Depth with Option A/B [mm] | 381,0 | 381,0 | |
| kVA | 157 | 157 | |
| Power Loss NO [W] | 2101 | 2101 | |
| Power Loss NO [W] | 2167 | 2167 | |
| Power Loss HO [W] | 1742 | 1742 | |
| Power Loss HO [W] | 1800 | 1800 | |
| Continuous Current (NO) [A] | 162 | 162 | |
| Intermittent Current (NO) [A] | 178 | 178 | |
| Continuous Current (NO) [A] | 155 | 155 | |
| Intermittent Current (NO) [A] | 170 | 170 | |
| Continuous Current (HO) [A] | 137 | 137 | |
| Intermittent Current (HO) [A] | 206 | 206 | |
| Continuous Current (HO) [A] | 131 | 131 | |
| Intermittent Current (HO) [A] | 196 | 196 | |
| Power Rating at 525-550V | 90kW | 90kW | |
| Power Rating at 575V | 125HP | 125HP | |
| Power Rating at 690V | 110kW | 110kW | |
| Calculated Gross Weight [kg] | 166.3 | ||
| Calculated Net Weight [kg] | 166 | ||
| ECCN EU | Y901 | Y901 | |
| ECCN US | 3A999.a | 3A999.a | |
| Vendor | ERR01 | Cannot Determine Vendor | |
| Recommended Factory | ERR01 | Cannot Determine Vendor | |
| Modelcode01 | FC-302N110T7E21H2BGC | ||
| Modelcode02 | XXXSXXXXA0BRCXXXXD0 | ||
| Recommended Plant | ERR01 | ERR01 |